On-site
Diagnostic Air Leakage Testing Checklist
Commercial
1. Build stage
It’s essential that the building is completely watertight with no large openings. This ensures accurate pressure readings and helps us pinpoint the source of any leakage. If you’re unsure about anything, feel free to ask for advice before booking.
2. Drawings
Please send us floor plans, sections, and elevations if you haven’t already. This helps us to accurately measure the surface area, leading to better results. Send these drawings to your Relationship Manager so we can calculate before the test.
3. Target
We can’t determine if we pass without an air leakage target. Please ask your SBEM assessor for this information and provide it to your Relationship Manager.
4. Power
Each plot will need power. We require 110v / 240v sockets by an external door that will be used to locate the fan. No power, no air leakage test.
5. Ventilation and temporary air sealing
Please temporarily cover all ventilation (including background) in the building. This will give the engineer enough time to help with any small fixes if needed. This includes any chimneys or log burner ventilation. Check all roof windows are shut, including any vents — this often gets missed by the engineers. We recommend using air sealing tape from airsealingexpert.co.uk.
6. Height
Any ventilation higher than 2.6m requires sealing prior to our arrival due to health and safety issues working at height restrictions.
7. Water
Please ensure water is in all the traps (sinks, toilets, and utility waste pipes) as it will affect your air leakage test and may cause unpleasant odours when we depressurise the building.
8. Trades and access
We need easy access to all plots that require testing. We understand finishing the development is crucial, but having the place to ourselves would help us detect leaks faster. If this isn’t possible we’re willing to cooperate with you.
9. Door
We require an external door frame of standard size to fit our square adjustable frame. You may need to modify the opening to suit our template. The minimum size opening is 700 x 1300mm, and the maximum is 1100 x 2400mm.
10. Parking
We need a parking spot within 20 metres of the plot we are testing, as the equipment is heavy and very expensive. If no parking can be provided please notify your relationship manager, as parking charges will be added to the final invoice.
11. Location and site address
We aim to arrive at the designated time window, so to help us be as efficient as we can, let us know if there are any difficulties finding the site. Ideally, send us what3words. For your certification records we will require the registered site address. Please ensure the correct address is used on all correspondence, as changes will incur an additional cost.
12. Signature
A site manager or representative must be present throughout the duration of the testing—for our own safety—and be able to provide a signature once we are finished.
Helpful videos
Find air leaks in your home
Get air tight, block & brick part 1
Get air tight, block & brick part 2
Get air tight, timber frame part 1
Smoke testing block & brick house
Should I have a pre-air test?
Best ways to find air leaks
When do I need an air leakage test?
Supersize commercial air testing
More bonus videos
More from us
Make things easier for you and keep it under one roof. Did you know that we offer a wide range of building compliance services?
Take a look